Specification of hydrodynamic force coefficients (Input Table)
Data description/conditions:
Identifier (1): (toggleable)
Identification name of data reference point
DRAG-C:
Hydrodynamic drag force coefficient cd
≥ 0. and < 5.
[Default: 0.7]
MASS-C:
Hydrodynamic mass force coefficient cm
≥ 0. and < 5.
[Default: 3.29]
LIFT-C:
Hydrodynamic lift force coefficient cl
≥ 0. and < 5.
[Default: 1.0]
(Lift force coefficient to be used for pipeline parts at or near the sea bed only. The resulting lift force acts in the positive Z-direction (so upward). For all other cases specify as 0.)
The coefficients specified at Identifier are applicable up to the next Identifier specification, meaning there is no interpolation of elements data between two reference points.