List of generated pipe dimension data based on elements list (Output Table)
Table description:
The output data table PIPEDIM provides a list, based on the generated elements list, of the pipe dimension data from the input data tables DIAM, WALL and DEADW.
The ratio value D/T relates to the relevant function error or warning.
The ratio value L/D can be used for accuracy estimation (see POLYDIF).
For small radius bends a warning is given if BENDPAR (or λ) is less than 0.2, as the accuracy of the bend behaviour modelling decreases in that case. This parameter λ is dependent on the diameter, wall thickness and bend radius.
where:
t |
= wall thickness of bend (nominal wall thickness minus corrosion tolerance) |
R |
= bend radius |
r |
= average pipe radius |
v |
= Poisson’s ratio of bend material |
This warning is a first indication of the bend behaviour. Other similar warnings may follow. See explanation sub Design Function 5.
H310522 (last modified: Sep 15, 2024)