Specification of maximum horizontal soil reaction along pipeline axis (Input Table)

Data description/conditions:

Identifier: (toggleable)

Identification name of data reference point

Required

RH1:

Maximum horizontal soil reaction just before and at data reference point

0.

RH2:

Maximum horizontal soil reaction just after data reference point

0. / Undefined

(If RH2=UNDEFINED it is assumed RH2 = RH1)

UNCF-L:

Uncertainty factor resulting in lower soil parameter RH

1. / Undefined if UNCF-H is specified

[Default: 1.6]

(If UNCF-L = UNDEFINED it is assumed that UNCF-L = UNCF-H. UNCF-L is used when the uncertainty in table UNCER is set to Low)

UNCF-H:

Uncertainty factor resulting in higher soil parameter RH

1. / Undefined if UNCF-L is specified

[Default: 1.6]

(If UNCF-H = UNDEFINED it is assumed UNCF-H = UNCF-L. UNCF-H is used when the uncertainty in table UNCER is set to High)

CFH1:

Lateral friction factor just before and at data reference point

0. and 1. / Undefined

(CFH1*R-LAT is considered as a lateral soil resistance additional to the specified RH. The UNCF factor is not applicable to CFH1.)
(If CFH1 = UNDEFINED , no additional  lateral soil resistance is added to the specified initial lateral soil resistance (see Table Description))

CFH2:

Lateral friction factor just after data reference point

0. and 1. / Undefined

(CFH2*R-LAT is considered as a lateral soil resistance additional to the specified RH. The UNCF factor is not applicable to CFH2.)
(If CFH2 = UNDEFINED , it is considered to be equal to CFH1)

VARAR:

Half band width accuracy allowance percentage for soil parameter

> 0. and < 50. / Undefined if RH1=RH2=0.

[Default: 5.]


H320171, last changed: 2009-07-16

See also:

Table description

Table error description