Specification of number and location of partially restrained connection in a SiS section (Input Table)

Data description/conditions:

REFIDENT:

Identification name of polygon point (n)

Optional

(Warning REFIDENT should be positioned on the inner pipe and within the SiS section)

ΔAX-L: (toggleable)

Distance from polygon point (REFIDENT) along pipeline axis to the first partially restrained connection in polygon line (n)

Optional

N-PRC:

Number of additional partially restrained connections

> 0 / Undefined = 0

(Each PRC is located on the inner pipe and should have an accompanying outer pipe element, perpendicular from the outer pipe

Warning When the connection elements on the outer pipe are too close to each other E200/41 will be reported.)

PRC-DIST:

Distance between consecutive PRCs

> 0. / Undefined if N-PRC = undefined

PRC-TYPE:

Type of partially restrained connection

Required / Prescribed names

 
(In the current version only 'Rollers' are allowed)


H200231, last changed: 11/4/2020

See also:

Table description

Table error description

Design Function 2